Colocation Services
RACK SERVERS
Shared Colocation Half -Rack Colocation Full-Rack Colocation
Gigabit switch port Redundant Gigabit switch ports Redundant Gigabit switch ports
Redundant power included 1kW Power included 2kW Power included
1x IPv4 Address included 8x IPv4 Address included 16 x IPv4 Address included
99.95% network uptime SLA 1 GB Bandwidth included 1 GB Bandwidth included
100% power uptime SLA 99.95% network uptime SLA 99.95% network uptime SLA
Redundant Connectivity 100% power uptime SLA 100% power uptime SLA
24×7 Manned Facility Security Redundant Connectivity Redundant Connectivity
24×7 Un-Escorted Access 24×7 Manned Facility Security 24×7 Manned Facility Security
- 24×7 Data Center access 24×7 Data Center access
- 24x7x365 Access Swipe Card (1 Included) 24x7x365 Access Swipe Card (1 Included)
FACILITIES

Electrical Power System

Data Center Electrical Design Services 2 Sources Electrical Power System from MEA “4-wired”  used  electrical system design A professional data center electrical design will protect your business by minimizing the risk of losing uptime. And also UPS 20 KVA supported included 

  • Power Distribution Units
  • Power Distribution Cabling
  • Cabinet Grounding
  • Branch Circuit Power Monitoring
  • Electrical Distribution Commissioning

Fire Extinguishing System

Novec™ 1230 Fire Protection Fluid, is a second generation clean agent fire extinguishing agent.  Novec™ 1230 is a chemical agent used primarily in total flooding systems and is the most environmentally benign of all the chemical agents. Novec™ 1230 is truly a real breakthrough in clean agent technology, a liquid at room temperature, it looks, feels and acts like water, allowing flexibility in recharge procedures. In particular our higher storage pressure at 34.5 bar (500psi) allows the greatest flexibility for the system design.

Generator System

Data Center Emergency Backup Generators: Diesel This is the most common industrial type available because they can provide more power capacity and output. They are readily available in a real disaster with the only exception that the military has priority over the diesel fuel if they need it. One other disadvantage is that the diesel fuelloses its effectiveness if it stays in the tank for a long time; as result constant maintenance is required to keep the diesel in good condition.

SECURITY

CCTV and Access Control Solution

video solutions which will ensure optimized solutions for the different areas in the data center such as
  • Perimeter
  • Building
  • Reception
  • Control room
  • Server hall
  • Cabinet
  • 24X7 Services support

DISASTER RECOVERY

Disaster recovery as a service (DRaaS)

is the replication and hosting of physical or virtual servers by a third party to provide failover in the event of a man-made or natural catastrophe. And Also joint the another ISPs for replicated data